Company
A small scale pharmaceutical unit in Gujarat. The unit is
manufacturing Mebendazole which is consumed as Anthelmintic
drug.
After the meeting with the representatives of Gujarat Cleaner
Production Centre, the industry came forward for CP-Exercise.
Process
Nitro Chlore Benzo Phenone obtained by the aryalation of
Nitro Chloro Benzoic Acid undergoes amination and reduction
to form 3,4,Diamino Benzophenone. Then it is condensed with
adduct to form Mebendazole
CP-Programme
AAfter complete study of process as per CP-methodology potentials
for CP-options were developed and evaluated afterwards. After
economical and technical feasibility analysis few options
were suggested to industry and the results that we got are
tremendous and very valuable for industry in current situation
prevailing in the Global Market.
CP-Results
- Thermic Fluid boiler and Steam boiler (single pass) were
the two boilers using for getting the temperature of 1600C.
There were several reasons which lead to CP-option of changing
boiler, like the temperature was 2630 C which was more than
required, very less efficiency i.e. 65% and loss of costly
high thermic oil while washing the Thermic Fluid Boiler
after every 2-3 batches. A three pass, automatic boiler
having super saturated heat at required temperature and
imported burner with required supply oxygen was selected
to install instead of those two boilers. This has given
the required temperature, 20% reduction in fuel consumption,
25 % increment in Efficiency and saving of 6000 liters of
water which was earlier used for washing after 2-3 days.
The investment made after this implementation was Rs.9,00,000/-
(one time), while they are saving Rs.1,89,000/year with
reduction in effluent load.
- The Natural Draft Wooden Cooling Tower was used for Benzene
and Methanol recovery before CP. A New cooling tower with
exhaust fan facility with 165 TR capacity is installed,
which has increased Benzene and Methanol recovery by 25%
and 15% respectively. Earlier both were going to environment.
This option was implemented at the cost of Rs.1,25,000(one
time) which has earned Rs.3,58,800/year.
- A walk through survey of plant, show the fugitive emission
of Thionyl chloride and Mebendazole. A glass lined storage
vessel, metering pump and lay down glass lined pipe line
and vacuum cleaner worth Rs.2, 56,000 (one time) has been
installed to cope up with emission problems. This has saved
Rs.10,25,000/year and increase environmental benefit in
terms of dusting & workers safety as well.
- An installation of chilling plant has been suggested
as CP-option with the purpose of recovery of Benzene and
Methanol and saving of power. Rs.10,00,000 is invested for
that which gives savings of Rs.23,57,756 (pay back period
six months). Also it has reduced Effluent load.
- By changing the scrubbing media, the industry is now
able to scrub the flue gas initially it was done with chilled
water and then with caustic slurry. This option has reduced
the amount of unscrubbed flue gases of SO2 and HCl in to
atmosphere. This is possible without investment with savings
of Rs.2,30,400.
- The segregation of valuable By-product called Aluminum
chloride/Aluminum hydroxide from waste stream lead to saving
of Rs.10, 00,000 without making any investment.
- Earlier the waste stream contained excess quantity of
adducts, Acetic acid, Methyl Chloro Formate and EDTA. An
appropriate quantity of several raw materials was decided
after the material balance was successfully carried out
in the industry. A tremendous amount of Rs.1.33 Crores has
been saved without any investment.
- A successful implementation of CP-tools has opened new
doors for the industry like the company is going for FDA
(USA) permission for certain products and also company is
doing expansion.
 |
Summary:-
Economical benefits
Investment : Rs.25,05,000(one time)
Saving : Rs.1, 98,00,000/year
Environmental benefits
Reduction in fugitive emission of Thionyl chloride,
Methyl chloro format.
Better recovery process of Benzene, Methanol, SO2,
HCl which were earlier added to the environment.
Savings of around 2400 KL Water
Reduction in COD,TDS and effluent quantity.
Improvement in Working Environment.
|
|